2.
Clin Oral Investig ; 26(4): 3651-3662, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34981252

RESUMO

OBJECTIVES: To compare the accuracy (trueness and precision) of direct digitization of four different dental gap situation with two IOS (intraoral scanner). MATERIALS AND METHODS: Four partially edentulous polyurethane mandible models were used: (1) A (46, 45, 44 missing), (2) B (45, 44, 34, 35 missing), (3) C (42, 41, 31, 32 missing), and (4) D (full dentition). On each model, the same reference object was fixed between the second molars of both quadrants. A dataset (REF) of the reference object was generated by a coordinate measuring machine. Each model situation was scanned by (1) OMN (Cerec AC Omnicam) and (2) PRI (Cerec Primescan AC) (n = 30). Datasets of all 8 test groups (N = 240) were analyzed using inspection software to determine the linear aberrations in the X-, Y-, Z-axes and angular deviations. Mann-Whitney U and two-sample Kolmogorov-Smirnov tests were used to detect differences for trueness and precision. RESULTS: PRI revealed higher trueness and precision in most of the measured parameters ([Formula: see text] 120.95 to 175.01 µm, [Formula: see text](x) - 58.50 to - 9.40 µm, [Formula: see text] (z) - 70.35 to 63.50 µm), while OMN showed higher trueness for [Formula: see text] (y) regardless of model situation (- 104.90 to 34.55 µm). Model D revealed the highest trueness and precision in most of the measured parameters regardless of IOS ([Formula: see text] 120.95 to 195.74 µm, [Formula: see text] (x) - 9.40 to 66.75 µm,[Formula: see text] (y) - 14.55 to 51.50 µm, [Formula: see text] (z) 63.50 to 120.75 µm). CONCLUSIONS: PRI demonstrated higher accuracy in the X- and Z-axes, while OMN depicted higher trueness in the Y-axis. For PRI, Model A revealed the highest distortion, while for OMN, Model B produced the largest aberrations in most parameters. Clinical relevance Current results suggest that both investigated IOS are sufficiently accurate for the manufacturing of tooth-borne restorations and orthodontic appliances. However, both hardware specifications of IOS and the presence of edentulous gaps in the dental model have an influence on the accuracy of the virtual model dataset.


Assuntos
Técnica de Moldagem Odontológica , Arcada Edêntula , Desenho Assistido por Computador , Análise de Dados , Arco Dental , Humanos , Imageamento Tridimensional , Modelos Dentários
3.
J Adv Prosthodont ; 13(5): 316-326, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34780580

RESUMO

PURPOSE: Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. MATERIALS AND METHODS: A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17-P13, P17-P23, P17-P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). RESULTS: Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). CONCLUSION: Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.

4.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-918853

RESUMO

PURPOSE@#Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla. @*MATERIALS AND METHODS@#A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference dataset (REF). Intraoral scans using Cerec Primescan AC (PRI) and Cerec AC Omnicam (OMN), as well as conventional impressions (scannable polyvinyl siloxane) were carried out (n = 25). Conventional impressions (E5I) and referring plaster casts were scanned with the inEOS X5 (E5M). All datasets were exported in STL and analyzed (Geomagic Qualify). Linear and angular differences were evaluated by virtually constructed measurement points in the centers of the hemispheres (P13, P17, P23, P27) and lines between the points (P17–P13, P17–P23, P17–P27). Kolmogorov-Smirnov test and Shapiro-Wilk test were performed to test for normal distribution, Kruskal-Wallis-H test, and Mann-Whitney-U test to detect significant differences in trueness, followed by 2-sample Kolmogorov-Smirnov test to detect significant differences in precision (P < .008). @*RESULTS@#Group PRI showed the highest trueness in linear and angular parameters (P < .001), while group E5I showed the highest precision (P < .001). @*CONCLUSION@#Intraoral scan data obtained using Primescan showed the highest trueness while the indirect digitization of impressions showed the highest precision. To enhance the workflow, indirect digitization of the impression itself appears to be a reasonable technique, as it combines fast access to the digital workflow with the possibility of functional impression of mucosal areas.